● NCC Smart IONM system is an intraoperative neuro monitoring system which helps reduce the risk of nerve damage during various of types of surgery and identify the integrity of nerve function before the end of surgery through monitoring triggered EMG activities in multiple cranial and peripheral nerves. Especially applied in thyroid surgery, ENT, oral and maxillofacial surgery or simple spine surgery.
● One box integrates 8 recording channels and 2 stimulation channels, making it easy to operate.
● During surgery, various sound settings such as event sound, stimulus sound, and EMG sound can help detect nerves by determining the relative position of the detection point and the nerve based on voice intensity.
● Real-time impedance testing and stimulus current measurement during surgery to ensure reliable monitoring.
● Built-in standard and customized templates make it easy to convert and handle various surgery types without sophisticated settings.
● During testing or playback, you can add waveform annotations to make the output report clearer and more thorough.
● Default parameters are automatically preset based on the type of surgery, but they can be adjusted for optimal performance.
● Touch and user-friendly interface
● Test and replay display
● Customizable parameter setting
By virtue of its powerful function, the NCC intraoperative nerve stimulation monitor provides strong support for intraoperative nerve monitoring. The instrument has a rich template built-in, which can easily adapt to various types of surgical needs. Recurrent laryngeal nerve injury is a common complication of thyroid and parathyroid surgery. Hoarseness, choking, decreased voice, or loss of voice may occur. Unilateral recurrent laryngeal nerve injury results in temporary or permanent vocal cord paralysis, bilateral damage can lead to suffocation and even be life-threatening. The introduction of intraoperative nerve monitoring not only makes the operation more reasonable, but also improves the safety and greatly reduces the doctor-patient disputes
Figure: Intraoperative nerve stimulation Monitor
Figure: Disposable probe / Endotracheal tube
Built-in rich surgical template, adapt to a variety of types of surgery, complex surgery one-button switch, 5 seconds fast response.
Automatic impedance test function, real-time monitoring module connection stability, reliable operation of equipment, eliminate signal interference.
Recurrent laryngeal nerve real-time monitoring: dynamic capture of nerve signal fluctuations, sensitivity up to 0.1 ma, accurate identification of small changes.
Abnormal signal immediate alarm: such as vocal cord paralysis signs and other risks early warning, doctors can immediately adjust the operation to avoid permanent damage.
Equipped with double stimulation channels, the vagus nerve and recurrent laryngeal nerve can be detected with“Double insurance”, which can significantly improve the monitoring accuracy.
Automatic labeling of EMG latency and amplitude, rapid analysis of surgical results, to provide doctors with key data support.
Automatic recording of monitoring data, support at any time playback, report output and print, easy to postoperative analysis, summary and case discussion.
• Reducing the risk of complications: the risk of recurrent laryngeal nerve injury during thyroid surgery is reduced, and the risk of death from bilateral injury approaches zero.
• Shorten the rehabilitation cycle: early intervention to reduce postoperative vocal cord dysfunction, the recovery efficiency of patients significantly improved.
• Reducing medical disputes: objective monitoring data provides a legal chain of evidence that significantly reduces the incidence of disputes.
0.1 ma sensitivity